1P+N RCBO

  • No auxiliary power required
  • Leakage & overcurrent protection
  • Stable electromagnetic tripping
  • Multiple sensitivity options
  • Type A / F / G / S available
  • 6kA / 10kA versions

Product Description

1P+N RCBO – Type A / F / G / S

CHYOYON 1P+N RCBO combines residual current and overcurrent protection in a compact design, suitable for residential and light commercial applications.
Designed according to IEC / EN 61009-1, it ensures reliable tripping performance and consistent protection in modern electrical distribution systems.

Technical Specifications

Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
Electromagnetic RCBO-Type A/F/G/S

StandardIEC / EN 61009-1
Number of Poles1P+N 
Breaking Capacity (Icn)6kA / 10KA
Rated Current (In)6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Residual Operating Current (IΔn)10mA /30mA / 100mA / 300mA
Residual Current TypeType AC / Type A / Type F
Time Delay TypeInstantaneous (no intentional delay)
Type G (≈10 ms delay)
Type S (≈40–200 ms delay)
Tripping CurveB Curve (3-5 In),
C Curve (5-10 In), D Curve (10-20 In)
Rated Voltage (Un)1P+N: 230V AC
Insulation Voltage (Ui)500V
Frequency50 / 60 Hz
Electrical / Mechanical Endurance2,000 / 10,000 operations
Degree of ProtectionIP20
Ambient Temperature−25°C to +55°C
Terminal Capacity1 – 35 mm² (solid or flexible)

StandardIEC / EN 61009-1
Number of Poles1P+N / 3P+N
Breaking Capacity (Icn)6kA / 10KA
Rated Current (In)6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Residual Operating Current (IΔn)30mA / 100mA / 300mA
Residual Current TypeType AC / Type A / Type F
Time Delay TypeInstantaneous (no intentional delay)
Type G (≈10 ms delay)
Type S (≈40–200 ms delay)
Tripping CurveB Curve (3-5 In),
C Curve (5-10 In), D Curve (10-20 In)
Rated Voltage (Un)1P+N: 230V AC
3P+N: 400 / 415V AC
Insulation Voltage (Ui)500V
Frequency50 / 60 Hz
Electrical / Mechanical Endurance2,000 / 10,000 operations
Degree of ProtectionIP20
Ambient Temperature−25°C to +55°C
Terminal Capacity1 – 35 mm² (solid or flexible)

Additional information

RCBO Series

1P+N RCBO

Product Description

CHOYON CYL6-80. A compact residual current circuit breaker designed to provide dependable protection against earth leakage faults in residential and light commercial installations. It ensures automatic disconnection in case of residual current imbalance, improving electrical safety and reducing potential fire risks.

Manufactured in accordance with IEC 61008-1 standards, this device delivers stable performance and reliable protection in modern DIN rail distribution systems.

Technical Specifications

Model Type IΔn (mA) In (A) Modules Curve Breaking Capacity
C Curve
CYB6L-63AC / A / F10, 30, 100, 30062C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300102C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300162C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300202C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300252C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300322C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300402C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300502C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300632C6kA / 10kA
B Curve
CYB6L-63AC / A / F10, 30, 100, 30062B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300102B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300162B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300202B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300252B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300322B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300402B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300502B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300632B6kA / 10kA