3P+N RCBO

  • No auxiliary power required
  • Leakage & overcurrent protection
  • Stable electromagnetic tripping
  • Designed for three-phase applications
  • Type A / F / G / S available
  • 6kA / 10kA versions

Product Description

3P+N RCBO – Type A / F / G / S

CHYOYON 3P+N RCBO provides combined residual current and overcurrent protection for three-phase systems, ensuring safe and stable operation in industrial and commercial environments.
Compliant with IEC / EN 61009-1, it delivers dependable performance for modern multi-phase electrical installations.

Technical Specifications

Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
Electromagnetic RCBO-Type A/F/G/S

StandardIEC / EN 61009-1
Number of Poles 3P+N
Breaking Capacity (Icn)6kA / 10KA
Rated Current (In)6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Residual Operating Current (IΔn)10mA /30mA / 100mA / 300mA
Residual Current TypeType AC / Type A / Type F
Time Delay TypeInstantaneous (no intentional delay)
Type G (≈10 ms delay)
Type S (≈40–200 ms delay)
Tripping CurveB Curve (3-5 In),
C Curve (5-10 In), D Curve (10-20 In)
Rated Voltage (Un)3P+N: 400 / 415V AC
Insulation Voltage (Ui)500V
Frequency50 / 60 Hz
Electrical / Mechanical Endurance2,000 / 10,000 operations
Degree of ProtectionIP20
Ambient Temperature−25°C to +55°C
Terminal Capacity1 – 35 mm² (solid or flexible)
ModelTypeIΔn (mA)In (A)ModulesCurveBreaking Capacity
C Curve
CYB6L-63AC / A / F10, 30, 100, 30062C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300102C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300162C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300202C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300252C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300322C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300402C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300502C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300632C6kA / 10kA
B Curve
CYB6L-63AC / A / F10, 30, 100, 30062B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300102B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300162B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300202B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300252B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300322B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300402B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300502B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300632B6kA / 10kA

Product Description

CHOYON CYL6-80. A compact residual current circuit breaker designed to provide dependable protection against earth leakage faults in residential and light commercial installations. It ensures automatic disconnection in case of residual current imbalance, improving electrical safety and reducing potential fire risks.

Manufactured in accordance with IEC 61008-1 standards, this device delivers stable performance and reliable protection in modern DIN rail distribution systems.

Technical Specifications

Model Type IΔn (mA) In (A) Modules Curve Breaking Capacity
C Curve
CYB6L-63AC / A / F10, 30, 100, 30062C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300102C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300162C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300202C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300252C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300322C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300402C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300502C6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300632C6kA / 10kA
B Curve
CYB6L-63AC / A / F10, 30, 100, 30062B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300102B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300162B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300202B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300252B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300322B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300402B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300502B6kA / 10kA
CYB6L-63AC / A / F10, 30, 100, 300632B6kA / 10kA

Related Products